Specifications:
| Power |
+ 24V DC ± 10% |
| Bezel |
Bezel IP 65 rated keypad |
|
Operating Temp |
0o
to 50o C |
|
Storage Temp |
-20o to 80o C |
|
Humidity |
10% to 90% (Non-condensing) |
|
Communication |
Two communication ports. (User configurable) |
|
Immunity to ESD |
Level 3 as per IEC1000-4-2 |
|
Immunity to Transients |
Level 3 as per IEC1000-4-4 |
|
Immunity to Radiated RF |
Level 3 as per IEC1000-4-3 |
|
Emission |
EN55011 CISPR A |
Universal
Analog Inputs: Software
Selectable
|
0-100 mV, 0-50 mV
0-20 mA, 4-20 mA
3-wire RTD (Alpha1, Alpha2)
Type B, R, S, E, J, K, N and T |
Analog Outputs:
mA |
4-20 mA
|
Digital Inputs:
Rated Input Voltage
Rated Input Current
Minimum ON Voltage
Minimum OFF Voltage
|
24V DC
10mA
10V
3.0V |
Digital Outputs:
Maximum Load current
Voltage drop at ON
Maximum Reverse Voltage
|
50mA
0.4V or less
6V Digital |
Outputs (Relay):
Ralay Rating
|
230V AC, 2 Amp. (max.) |

 
 
Programmability
The HIO unit
possess both Prizm (Operator interface) as well
as programmable logic features. User can
implement logic, specific to application using
standard Ladder programming. The HIO unit has
four High speed counters (5 K Hz.), hundreds of
timers and counters, thousands of internal
coils, retentive and nonretentive memory and PID
functionality. A programming logic task can be
programmed for continuous scanning, or only when
a specific screen is showing. User can also
include Programmable logic task in power on as
well as Global task. The HIO operator interface
functions revolve around Screens and Tasks that
can be assigned to keys, screens and
application. The HIO can also display an Alarm
condition. |
Supported Tasks are listed below:
1. Go to
Screen
2. Go to Next Screen
3. Go to Previous Screen
4. Write Value to a Tag
5. Add a Constant to Tag
6. Subtract a Constant from Tag
7. Add Tag B to Tag A
8. Subtract Tag B from Tag A
9. Turn Bit On
10. Turn Bit Off
11. Toggle Bit |
12. Copy
Tag B to Tag A
13. Swap Tag A and Tag B
14. Print Data
15. Set RTC
16. Copy Tag to STR
17. Copy Tag to LED
18. Delay
19. Wait
20. Copy Recipe Blk to PLC Blk
21. Copy PLC Blk to Recipe Blk
22. Execute PLC Logic Block. |
|
Digital I/O
The HIO series can have up to 16 digital inputs
and up to 12 digital outputs. Digital inputs are
high impedence 24 V DC and outputs are either
relay (Only NO), open collector or combination
of both.
Analog I/O
HIO series supports up to 4 analog inputs and up
to 2 analog outputs. Analog inputs are
4-20mA, mV,
Thermocouple and RTD. Analog outputs are 4-20 mA.
Keys Tasks
Keys in HIO can be assigned Tasks for three
instances: when key is pressed once, while key
is pressed and when key is released. Multiple
tasks can be assigned to a key. Tasks can be
assigned to a combination of two keys. Also
different screens can have different key
definitions. Keys can have password protection.
In addition to above-mentioned tasks, Key’s
specific tasks can be defined for keys. These
include tasks for data entry, alarm management
etc. These definitions allow complete
flexibility in cursor control and key operations
when changing data.
Screens
Up to 65535 screens can be defined in HIO.
Screen Tasks can be assigned before showing a
screen, while showing a screen and after hiding
a screen. Various types of objects can be
defined on the screen. Objects include plain
text objects, Data display (coil status,
register value, register dependent text), Data
entry objects, Alarm objects. Two screens can be
associated to avoid duplication of screens and
objects.
Data entry objects can have limits and math
associated. Various types of data formats are
available which help user to edit data easily.
Float data entry is also possible.
Alarms
Up to 256 alarms (16 for text models) can be
defined in HIO.
Alarms can either be consecutive or discrete.
User-friendly alarm object can be defined on the
display. Optional Alarm logging along with on /
off timers is also available. Keys can be
assigned to acknowledge alarm, print alarm, view
next / previous alarm etc.
Dual Port Support
HIO units have two communication
ports. Both the ports can be configured as
RS232, RS485 / RS422. Both the COM ports can
also be defined as programming port or to
connect a Printer / PLC / SCADA / Drive etc.
Drivers can be downloaded in HIO units for Dual
Port application
Configuration Software
HIO unit has to be configured before its use in
any system.
Complete configuration consists of defining:
1. HIO Settings
2. PLC node
3. Tag Database
4. Global Keys
5. Alarms
6. Global and Power-on Task list
7. Screens and Screens Task-List, Screen keys,
if required.
The complete configuration is stored as an
Application. This application is downloaded in
HIO.
Prizm32 is a compact, Windows® based software to
configure the HIO Series Interfaces. Prizm32’s
tools and easy approach can help you create your
applications quickly and easily. By using some
of Prizm32’s new features, you can be more
effective in what you need. Whether you need a
small application to monitor data or a bigger
application for both monitoring and changing
data in your PLC, Prizm32 has it all.
With Prizm32 you can get started quickly to use
your Prizm Interfaces.
HIO user should follow the given procedure to
configure and use HIO units:
1. Create an application
2. Connect IBM cable
3. Download Firmware
4. Download application.
Other Items required for HIO
configuration
1. HIO unit
2. Prizm32
3. IBM Cable (Part codes: IBM 0909-1 or IBM
0925-1)
System requirements for
Prizm32 are:
Windows Version : Microsoft Windows® NT / 2000 /
XP
Processor : PENTIUM or higher
Mouse : Required
RAM : 64 MB or more
Display resolution : 800 x 600 (VGA) or better
Display colors : 256 colors or more |
|
|
Model |
Display |
Digital Inputs |
Digital Outputs |
Analog Inputs |
Analog Outputs |
Dimensions |
Part Number |
|
HIO005
|
128 x 64 px. (1.25” g*)
|
6
|
6
|
1
|
1
|
48 x 48 x 76
|
HIO005-0606-0101-U-B-C-00
|
|
HIO050
|
20 x 4 (Text)
|
16
|
12
|
4
|
2
|
183 x 101 x 37
|
HIO050-1612-0402-U-B-C-00
|
|
HIO140
|
128 x 64 px.
(3” Graphical)
|
16
|
12
|
4
|
2
|
183 x 101 x 37
|
HIO140-1612-0402-U-B-R-00
|
|
HIO230
|
192 X 64 px.
(4.1” Graphical)
|
16
|
12
|
4
|
0
|
140 x 77 x 35
|
HIO230-1612-0400-U-B-C-00-S2
|
The models shown above and
in the purchase section are the ones we normally hold in stock.
The information sheet shows are models. If you require a model
not normally stocked please contact us for a price. Delivery for
non stocked items is normally 3 to 4 weeks
Download Information Sheet
PURCHASING THE HIO OPERATOR PANELS
All prices are in Australian Dollars. Prices do not include GST (Goods and
Services Tax). 10% GST applies to goods delivered in Australia. Australian GST is not paid
on shipments despatched to an international destination. You can check the exchange rate
by going to http://www.x-rates.com
|